Table of Contents Table of Contents
Previous Page  7 / 68 Next Page
Information
Show Menu
Previous Page 7 / 68 Next Page
Page Background ELECTRIC.IE

• The Magazine & Website for the Irish Electrical Industry •

5

Demesne Electrical

Are you using LSF or LSHF Cables On Site

?

I

f the answer to the above

question is YES, then you

should consider protecting those

cables with an LSHF Flexible

Conduit.

The move to LSF/LSHF/LS0H cables

has come about due to demand

for safety in public areas, such as

hospitals, schools, train stations

and on public transport. The risk

of poisonous fumes and thick black

smoke can be a greater risk to lives

–Šƒ –Šƒ– ‘ˆ Ƥ”‡ ƒŽ‘‡Ǥ

LSF stands for Low Smoke Fumes -

in regard to control, signal and data

cables, LSF cables and conduits are

ƒ†‡ ˆ”‘ ƒ ‘†‹Ƥ‡† ˜‡”•‹‘ ‘ˆ

Ǥ

These LSF cables/conduits can

•–‹ŽŽ ‰‹˜‡ ‘ơ Žƒ”‰‡ ƒ† †ƒ‰‡”‘—•

amounts of thick black smoke along

with hydrogen chloride gas when

burned.

Black smoke can obscure emergency

exits and hydrogen chloride can

be deadly to people who come into

contact with it.

LSHF stands for Low Smoke

Halogen Free, while LS0H stands

for Low Smoke Zero Halogen. When

these cables or conduits are exposed

–‘ Ƥ”‡ǡ –Ї› ‡‹– ‘ ‘”‡ –Šƒ ͜Ǥ͡τ

hydrogen chloride.

Clause 527 of the National Wiring

Rules deals with selection and

erection of wiring systems to

‹‹‹•‡ –Ї •’”‡ƒ† ‘ˆ Ƥ”‡Ǥ Š‹•

encompasses conduits/trunkings.

Cables must comply with I.S 201 and

conduits/trunkings must comply

with EN 50086-1 for conduits or EN

50085-1 for trunkings.

Nothing in the regulations states

that LSHF or LS0H conduits MUST

be used in public buildings or

where LSF/LSHF cables are being

installed, however, it makes sense

that halogen free cables should be

safely protected.

With this in mind, Demesne

އ…–”‹…ƒŽ ƒ”‡ –Ї Ƥ”•– ‡Ž‡…–”‹…ƒŽ

distributor in Ireland to import

a complete range of Low Smoke

Halogen Free Flexible Conduit and

Glands to suit.

–‡”ƪ‡š

Ž‡š‹„Ž‡ ‘†—‹–•

Ї –‡”ƪ‡š ”ƒ‰‡ ‹• †‡•‹‰‡†

for insulation, mechanical

protection and environmental

preservation of cables in the

electrical installation of machinery,

industrial equipment and

telecommunications.

Ȉ ƒ†‡ ‘ˆ •’‡…‹ƒŽŽ› ‘†‹Ƥ‡†

’‘Ž›ƒ‹†‡ ȋ ͢Ȍ

Ȉ ’‡…‹ƒŽ ’ƒ–‡–‡† ’”‘Ƥއȝ ˆ‘”

housing the O-ring sealing to

’”‘˜‹†‡ ƒ Š‹‰Š‡” ’”‘–‡…–‹‘

• Free of halogen, phosphorus and

cadmium

Ȉ ‡ŽˆǦ‡š–‹‰—‹•Š‹‰ ȋ ͞ ƒ……Ǥ –‘

ͥ͠Ȍ

• Temperature range: -40ºC to

φ͙͜͝͡ ȋ͙͜͝͡ •Š‘”– –‡”Ȍ

Ȉ

”‡•‹•–ƒ– ȋ„Žƒ……‘Ž‘—”Ȍ

• Colours: Black ex stock Demesne

and grey available on request.

Ї –‡”ƪ‡š ‹‘˜ƒ–‹˜‡ ’ƒ–‡–‡†

system stands out from existing

ones through three exclusive

†‹ơ‡”‡–‹ƒŽ…Šƒ”ƒ…–‡”‹•–‹…•ǣ

1-

High traction resistance (for extra

ƒˆ‡–›Ȍ —”

…‘‡…–‘”•

hold the corrugated conduit all

around its entire perimeter. This

allows a better distribution of the

tensile forces and thus an increase

of the installation safety.

2-

͢͢ –‘ ͤ͢Ȁ ͥ͢ ”‘–‡…–‹‘

with a single connector. The

–‡”ƪ‡š •›•–‡ ƒŽŽ‘™• –Š”‡‡ ™ƒ–‡”

tightness levels with the same

connector, by simply adding the

ͤ͢ ƒ† ͥ͢ ’”‘–‡…–‹‘ Ǧ”‹‰

on the last groove of the conduit’s

•’‡…‹ƒŽ ’ƒ–‡–‡† ’”‘Ƥއ ƒ† ƒ

sealing washer at the base of the

…‘‡…–‘”Ǥ Š‹•…Šƒ”ƒ…–‡”‹•–‹…‘ơ‡”•

—’ –‘ ƒ ͥ͢ ’”‘–‡…–‹‘ ƒ– ƒ Ž‘™

cost.

3-

Quick and easy assembly and

removal of the conduit. Our

…‘‡…–‘”• ƒŽ•‘ ‘ơ‡” ƒ “—‹…

assembly and removal of the

conduit thanks to the unique «easy-

click» system. With a light manual

pressure over unlocking push-

ring the conduit is easily removed

without need of any tool.

To register your interest in our

range of LSHF Flexible Conduit

please send an email to

Ian@Demesne.ie

or call us on 01-4047700